Skip to main content

Research Repository

Advanced Search

All Outputs (6)

Experimental setup of continuous ultrasonic monitoring for corrosion assessment (2017)
Conference Proceeding
Suchato, N., Kalashnikov, A., Light, R., & Sharples, S. (in press). Experimental setup of continuous ultrasonic monitoring for corrosion assessment.

The paper is devoted to the ultrasonic monitoring of accelerated corrosion. In order to achieve non-uniform corrosion (high surface roughness), passivation was applied to the corroding surface. A dedicated electronic multiplexed four channel front en... Read More about Experimental setup of continuous ultrasonic monitoring for corrosion assessment.

Experimental evaluation of ultrasonic oscillating temperature sensors (UOTS) under cyclically changing temperatures (2015)
Conference Proceeding
Hashmi, A., Kalashnikov, A. N., & Light, R. A. (2015). Experimental evaluation of ultrasonic oscillating temperature sensors (UOTS) under cyclically changing temperatures.

In contrast to most conventional temperature sensors, which need to come to thermal equilibrium with the medium of interest to report its temperature, UOTS interrogate the medium based on the propagation speed of ultrasound, and will return temperatu... Read More about Experimental evaluation of ultrasonic oscillating temperature sensors (UOTS) under cyclically changing temperatures.

Rapid wide-field heterodyne interferometry with custom 2D CMOS camera (2015)
Journal Article
Zhang, J., See, C. W., Smith, R. J., Johnston, N. S., Pitter, M. C., Somekh, M. G., & Light, R. A. (2015). Rapid wide-field heterodyne interferometry with custom 2D CMOS camera. Electronics Letters, 51(6), 479-480. https://doi.org/10.1049/el.2015.0268

© The Institution of Engineering and Technology 2015. A wide-field pseudo-heterodyne interference contrast microscope is described, which employs a complementary metal-oxide semiconductor (CMOS) phase-sensitive camera. The use of multiple wells in th... Read More about Rapid wide-field heterodyne interferometry with custom 2D CMOS camera.

Widefield two laser interferometry (2014)
Journal Article
Patel, R., Achamfuo-Yeboah, S., Light, R. A., & Clark, M. (2014). Widefield two laser interferometry. Optics Express, 22(22), https://doi.org/10.1364/OE.22.027094

A novel system has been developed that can capture the wide- field interference pattern generated by interfering two independent and incoherent laser sources. The interferograms are captured using a custom CMOS modulated light camera (MLC) which is c... Read More about Widefield two laser interferometry.

Highly sensitive multipoint real-time kinetic detection of Surface Plasmon bioanalytes with custom CMOS cameras (2014)
Journal Article
Wang, J., Smith, R. J., Light, R. A., Richens, J. L., Zhang, J., O'Shea, P., …Somekh, M. G. (2014). Highly sensitive multipoint real-time kinetic detection of Surface Plasmon bioanalytes with custom CMOS cameras. Biosensors and Bioelectronics, 58, 157-164. https://doi.org/10.1016/j.bios.2014.02.042

Phase sensitive Surface Plasmon Resonance (SPR) techniques are a popular means of characterizing biomolecular interactions. However, limitations due to the narrow dynamic range and difficulty in adapting the method for multi-point sensing have restri... Read More about Highly sensitive multipoint real-time kinetic detection of Surface Plasmon bioanalytes with custom CMOS cameras.