Skip to main content

Research Repository

Advanced Search

All Outputs (3)

Exploring the Bias: How Skin Colour Influences Oxygen Saturation Readings via Monte Carlo Simulations (2024)
Journal Article
Swamy, S., Liu, C., Correia, R., Hayes-Gill, B., & Morgan, S. (2024). Exploring the Bias: How Skin Colour Influences Oxygen Saturation Readings via Monte Carlo Simulations. Journal of Biomedical Optics, 29(S3), Article S33308. https://doi.org/10.1117/1.JBO.29.S3.S33308

Significance: Understanding the root cause of reported oxygen saturation (SpO2) overestimation in heavily pigmented skin types to devise solutions toward enabling equity in pulse oximeter design.

Aim: To gain theoretical insights into the effect o... Read More about Exploring the Bias: How Skin Colour Influences Oxygen Saturation Readings via Monte Carlo Simulations.

Fabrication and assessment of a bio-inspired synthetic tracheal tissue model for tracheal tube cuff leakage testing (2024)
Journal Article
Agbiki, T., Arm, R., Hewson, D. W., Erdody, S., Norris, A. M., Correia, R., …Morgan, S. P. (2024). Fabrication and assessment of a bio-inspired synthetic tracheal tissue model for tracheal tube cuff leakage testing. BJA Open, 10, Article 100290. https://doi.org/10.1016/j.bjao.2024.100290

Introduction
Leakage of orogastric secretions past the cuff of a tracheal tube is a contributory factor in ventilator-associated pneumonia. Current bench test methods specified in the International Standard for Anaesthetic and Respiratory Equipment... Read More about Fabrication and assessment of a bio-inspired synthetic tracheal tissue model for tracheal tube cuff leakage testing.

Highly sensitive optical fibre Bragg grating contact pressure sensor embedded in a polymer layer: modelling and experimental validation (2024)
Journal Article
Abeywardena, C., Zhang, Q., Korposh, S., Morgan, S., Bull, S., & Correia, R. (2024). Highly sensitive optical fibre Bragg grating contact pressure sensor embedded in a polymer layer: modelling and experimental validation. Results in Optics, 14, Article 100604. https://doi.org/10.1016/j.rio.2024.100604

This paper discusses mathematical modelling and experimental validation of a highly sensitive optical fibre Bragg grating (FBG) contact pressure sensor developed for healthcare applications. Bare FBGs are not very sensitive to pressure (~ 3x10-3 nm/M... Read More about Highly sensitive optical fibre Bragg grating contact pressure sensor embedded in a polymer layer: modelling and experimental validation.