Skip to main content

Research Repository

Advanced Search

All Outputs (11)

Fillet Radius Impact of Rectangular Insulated Wires on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors (2024)
Journal Article
Naderiallaf, H., Degano, M., Gerada, C., & Gerada, D. (2024). Fillet Radius Impact of Rectangular Insulated Wires on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors. IEEE Transactions on Dielectrics and Electrical Insulation, 1-1. https://doi.org/10.1109/tdei.2024.3355032

This contribution elucidates the impact of the fillet radius, a geometric feature of rectangular insulated wires not commonly considered, on the partial discharge inception voltage (PDIV) in low-voltage machine turn-to-turn winding insulation. Initia... Read More about Fillet Radius Impact of Rectangular Insulated Wires on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors.

Modeling Humidity Impact on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors at Different Temperatures (2023)
Journal Article
Naderiallaf, H., Ji, Y., Giangrande, P., & Galea, M. (2023). Modeling Humidity Impact on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors at Different Temperatures. IEEE Transactions on Dielectrics and Electrical Insulation, 1-1. https://doi.org/10.1109/tdei.2023.3338138

This paper models the partial discharge inception voltage (PDIV) as a function of ambient humidity ( H ) at various temperatures ( Ts ) using Schumann’s streamer inception criterion (SCSIC) for turn-to-turn insulation, which is the most vulnerable pa... Read More about Modeling Humidity Impact on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors at Different Temperatures.

Air Pressure Impact on the Avalanche Size for Turn-to-Turn Insulation of Inverter-Fed Motors (2023)
Journal Article
Naderiallaf, H., Ji, Y., Giangrande, P., & Galea, M. (2024). Air Pressure Impact on the Avalanche Size for Turn-to-Turn Insulation of Inverter-Fed Motors. IEEE Transactions on Dielectrics and Electrical Insulation, 31(1), 85-94. https://doi.org/10.1109/TDEI.2023.3324287

This paper endeavours to illuminate the variations of various streamer inception parameters (SIPs) with respect to air pressure based on Schumann’s streamer inception criterion (SCSIC). The results based on measured PDIV values and using electric fie... Read More about Air Pressure Impact on the Avalanche Size for Turn-to-Turn Insulation of Inverter-Fed Motors.

Temperature Impact on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors: from Ground Level to Cruising Altitude (2023)
Journal Article
Naderiallaf, H., Ji, Y., Giangrande, P., & Galea, M. (2024). Temperature Impact on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors: from Ground Level to Cruising Altitude. IEEE Transactions on Dielectrics and Electrical Insulation, 31(2), 1044-1053. https://doi.org/10.1109/TDEI.2023.3313569

Considering the turn-to-turn insulation as the most susceptible part to the failure of the electrical machine’s insulation system in inverter-fed motors, this paper aims to elucidate the effect of temperature ( T ) on the streamer inception parameter... Read More about Temperature Impact on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors: from Ground Level to Cruising Altitude.

Assessment of Edgewise Insulated Wire Bend Radius Impact on Dielectric Properties of Turn-to-Turn Insulation through Thermal Ageing (2023)
Journal Article
Naderiallaf, H., Degano, M., & Gerada, C. (2023). Assessment of Edgewise Insulated Wire Bend Radius Impact on Dielectric Properties of Turn-to-Turn Insulation through Thermal Ageing. IEEE Transactions on Dielectrics and Electrical Insulation, https://doi.org/10.1109/TDEI.2023.3309780

This study aims to evaluate the impact of the bending radius of edgewise insulated wires on dielectric properties such as partial discharge inception voltage (PDIV), partial discharge extinction voltage (PDEV), dielectric dissipation factor (DDF), an... Read More about Assessment of Edgewise Insulated Wire Bend Radius Impact on Dielectric Properties of Turn-to-Turn Insulation through Thermal Ageing.

PDIV Modelling for Rectangular Wire Turn-to-Turn Insulation of Inverter-Fed Motors through Thermal Ageing (2023)
Journal Article
Naderiallaf, H., Degano, M., & Gerada, C. (2023). PDIV Modelling for Rectangular Wire Turn-to-Turn Insulation of Inverter-Fed Motors through Thermal Ageing. IEEE Transactions on Dielectrics and Electrical Insulation, 1-10. https://doi.org/10.1109/tdei.2023.3307048

This contribution develops the partial discharge inception voltage (PDIV)-FEM-based model based on Schumann’s streamer inception criterion (SCSIC) with respect to thermal ageing time (TAGT) or the insulation lifetime for the turn-to-turn insulation o... Read More about PDIV Modelling for Rectangular Wire Turn-to-Turn Insulation of Inverter-Fed Motors through Thermal Ageing.

Characterization of PDIV, PDEV and RPDIV in Insulated Wires under Unipolar Repetitive Square Wave Excitations for Inverter-Fed Motors (2023)
Journal Article
Naderiallaf, H., Giangrande, P., & Galea, M. (2023). Characterization of PDIV, PDEV and RPDIV in Insulated Wires under Unipolar Repetitive Square Wave Excitations for Inverter-Fed Motors. IEEE Access, 11, 51047-51063. https://doi.org/10.1109/ACCESS.2023.3279886

The behaviour of partial discharge inception voltage (PDIV), partial discharge extinction voltage (PDEV) and repetitive partial discharge inception voltage (RPDIV) as a function of exposure/poling time under unipolar repetitive square wave excitation... Read More about Characterization of PDIV, PDEV and RPDIV in Insulated Wires under Unipolar Repetitive Square Wave Excitations for Inverter-Fed Motors.

Glass Fibre Insulated Wire Assessment Under Partial Discharges Activity via Dielectric Dissipation Factor Measurements (2022)
Conference Proceeding
Naderiallaf, H., Giangrande, P., & Galea, M. (2022). Glass Fibre Insulated Wire Assessment Under Partial Discharges Activity via Dielectric Dissipation Factor Measurements. In 2022 9th International Conference on Condition Monitoring and Diagnosis (CMD 2022) (98-102). https://doi.org/10.23919/CMD54214.2022.9991482

This experimental study evaluates the ageing rate associated with partial discharges (PD) activity for a Type-II insulated wire (i.e., Glass fibre), relying on the dielectric dissipation factor (DDF) and capacitance tip-up measurements. The employed... Read More about Glass Fibre Insulated Wire Assessment Under Partial Discharges Activity via Dielectric Dissipation Factor Measurements.

Investigating the Effect of Waveform Characteristics on PDEV, PDIV and RPDIV for Glass Fibre Insulated Wire (2022)
Conference Proceeding
Naderiallaf, H., Giangrande, P., & Galea, M. (2022). Investigating the Effect of Waveform Characteristics on PDEV, PDIV and RPDIV for Glass Fibre Insulated Wire. In 2022 International Conference on Electrical Machines (ICEM 2022) (1327-1333). https://doi.org/10.1109/icem51905.2022.9910752

The trends of partial discharge extinction voltage (PDEV), partial discharge inception voltage (PDIV) and repetitive partial discharge inception voltage (RPDIV) as a function of duty cycle, frequency, and rise time are experimentally investigated in... Read More about Investigating the Effect of Waveform Characteristics on PDEV, PDIV and RPDIV for Glass Fibre Insulated Wire.

Experimental considerations on the possible impact of space charge accumulation on partial discharges activity for wire insulations (2022)
Conference Proceeding
Naderiallaf, H., Giangrande, P., & Galea, M. (2022). Experimental considerations on the possible impact of space charge accumulation on partial discharges activity for wire insulations. In 2022 IEEE 4th International Conference on Dielectrics (ICD 2022) (82-85). https://doi.org/10.1109/icd53806.2022.9863223

The impact of space charge accumulation caused by unipolar square waveform excitation on partial discharge inception voltage (PDIV) and partial discharge extinction voltage (PDEV) for one Type-II insulated wire, i.e., Glass fibre and one Type-I insul... Read More about Experimental considerations on the possible impact of space charge accumulation on partial discharges activity for wire insulations.

A Contribution to Thermal Ageing Assessment of Glass Fiber Insulated Wire Based on Partial Discharges Activity (2022)
Journal Article
Naderiallaf, H., Giangrande, P., & Galea, M. (2022). A Contribution to Thermal Ageing Assessment of Glass Fiber Insulated Wire Based on Partial Discharges Activity. IEEE Access, 10, 41186-41200. https://doi.org/10.1109/ACCESS.2022.3167698

This paper aims to evaluate a Type-II insulated wire (i.e., Glass fibre insulated wire) as a function of thermal ageing time based on partial discharges (PD) activity. Partial discharge inception voltage (PDIV), partial discharge extinction voltage (... Read More about A Contribution to Thermal Ageing Assessment of Glass Fiber Insulated Wire Based on Partial Discharges Activity.