Abstract

This paper describes the design process of a 10 kW 19000 rpm high power density surface mounted permanent magnet synchronous machine for a directly coupled pump application. In order to meet the required specifications, a compact machine, with cooling channels inside the slots and flooded airgap, has been designed through finite element optimization. For high power density, high speed machines, an accurate evaluation of the power losses and the electromechanical performance is always extremely challenging. In this case, the completely flooded application adds to the general complexity. Therefore this paper deals with a detailed losses analysis (copper, core, eddy current and mechanical losses) considering several operating conditions. The experimental measurements of AC copper losses as well as the material properties (BH curve and specific core losses), including the manufacturing process effect on the stator core, are presented. Accurate 3D finite element models and computational fluid dynamics analysis have been used to determine the eddy current losses in the rotor and windage losses respectively. Based on these detailed analysis, the no load and full load performance are evaluated. The experimental results, on the manufactured prototype, are finally presented to validate the machine design.

Citation

Al-Timimy, A., Giangrande, P., Degano, M., Zeyuan, X., Galea, M., Gerada, C., …Xia, L. (2019). Design and losses analysis of a high power density machine for flooded pump applications. IEEE Transactions on Industry Applications, 54(4), 3260-3270. https://doi.org/10.1109/TIA.2018.2821623

Journal Article Type Article
Acceptance Date Mar 21, 2018
Online Publication Date Mar 30, 2018
Publication Date Jul 1, 2019
Deposit Date Apr 10, 2018
Publicly Available Date Apr 10, 2018
Journal IEEE Transactions on Industry Applications
Print ISSN 0093-9994
Electronic ISSN 1939-9367
Publisher Institute of Electrical and Electronics Engineers
Peer Reviewed Peer Reviewed
Volume 54
Issue 4
Pages 3260-3270
DOI https://doi.org/10.1109/TIA.2018.2821623
Keywords High power density, high speed, losses calculation, performance analysis, permanent magnet motors
Public URL https://nottingham-repository.worktribe.com/output/922034
Publisher URL https://ieeexplore.ieee.org/abstract/document/8328844/
Additional Information © 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.