Skip to main content

Research Repository

See what's under the surface

Advanced Search

Investigation of indoor air qality and the identification of influential factors at primary schools in the North of China

Peng, Zhen; Deng, Wu; Tenorio, Rosangela

Authors

Zhen Peng

Wu Deng

Rosangela Tenorio



Abstract

Over 70% of a pupil’s school life is spent inside a classroom, and indoor air quality has a significant impact on students’ attendance and learning potential. Therefore, the indoor air quality in primary school buildings is highly important. This empirical study investigates the indoor air quality in four naturally ventilated schools in China, with a focus on four parameters: PM2.5, PM10, CO2, and temperature. The correlations between the indoor air quality and the ambient air pollution, building defects, and occupants’ activities have been identified and discussed. The results indicate that building defects and occupants’ activities have a significant impact on indoor air quality. Buildings with better air tightness have a relatively smaller ratio of indoor particulate matter (PM) concentrations to outdoor PM concentrations when unoccupied. During occupied periods, the indoor/outdoor (I/O) ratio could be larger than 1 due to internal students’ activities. The indoor air temperature in winter is mainly determined by occupants’ activities and the adiabatic ability of a building’s fabrics. CO2 can easily exceed 1000 ppm on average due to the closing of windows and doors to keep the inside air warmer in winter. It is concluded that improving air tightness might be a way of reducing outdoor air pollutants’ penetration in naturally ventilated school buildings. Mechanical ventilation with air purification could be also an option on severely polluted days.

Journal Article Type Article
Publication Date Jul 5, 2017
Journal Sustainability
Electronic ISSN 2071-1050
Publisher MDPI
Peer Reviewed Peer Reviewed
Volume 9
Issue 7
APA6 Citation Peng, Z., Deng, W., & Tenorio, R. (2017). Investigation of indoor air qality and the identification of influential factors at primary schools in the North of China. Sustainability, 9(7), doi:10.3390/su9071180
DOI https://doi.org/10.3390/su9071180
Keywords indoor air quality; primary school; building air tightness; internal activities; air pollutants
Publisher URL https://doi.org/10.3390/su9071180
Copyright Statement Copyright information regarding this work can be found at the following address: http://creativecommons.org/licenses/by/4.0