Impacts of dynamic interactions on the predicted thermal performance of earth–air heat exchangers for preheating, cooling and ventilation of buildings

Gan, Guohui

Impacts of dynamic interactions on the predicted thermal performance of earth–air heat exchangers for preheating, cooling and ventilation of buildings Thumbnail


Authors

GUOHUI GAN GUOHUI.GAN@NOTTINGHAM.AC.UK
Associate Professor



Abstract

Earth–air tunnel ventilation is an energy efficient ventilation technique that makes use of relatively stable soil temperature in shallow ground for preheating and cooling of supply air to a building. During operation, an earth–air heat exchanger interacts with the soil and atmosphere and the performance varies with the soil and atmospheric conditions. A computer program has been developed for modelling of coupled heat and moisture transfer in soil and for simulation of the dynamic thermal performance of an earth–air heat exchanger for preheating and cooling of a building. The impacts of dynamic interactions between the heat exchanger, soil and atmosphere are illustrated from the comparison of the heat transfer rate, heat exchanger temperature and supply air temperature through the heat exchanger for both preheating and cooling. It is shown that neglecting the interactions between the heat exchanger, soil and supply air would over predict the thermal performance of an earth–air heat exchanger. Neglecting the interactions between the soil surface and atmosphere while assuming axi-symmetric distributions of heat and moisture transfer as well as soil properties around the heat exchanger is not only unrealistic but also would fail to produce reliable data for long-term operational performance of the earth–air heat exchanger installed in shallow ground. The performance of an earth–air tunnel ventilation system can be enhanced when operated for both winter preheating and summer cooling of a building.

Citation

Gan, G. (in press). Impacts of dynamic interactions on the predicted thermal performance of earth–air heat exchangers for preheating, cooling and ventilation of buildings. International Journal of Low-Carbon Technologies, Article ctv029. https://doi.org/10.1093/ijlct/ctv029

Journal Article Type Article
Acceptance Date Oct 24, 2015
Online Publication Date Nov 24, 2015
Deposit Date Jul 6, 2016
Publicly Available Date Jul 6, 2016
Journal International Journal of Low-Carbon Technologies
Print ISSN 1748-1317
Electronic ISSN 1748-1325
Publisher Oxford University Press
Peer Reviewed Peer Reviewed
Article Number ctv029
DOI https://doi.org/10.1093/ijlct/ctv029
Keywords earth–air heat exchanger; heating and cooling; building ventilation; heat transfer; moisture transfer; dynamic interaction
Public URL https://nottingham-repository.worktribe.com/output/765517
Publisher URL http://ijlct.oxfordjournals.org/content/early/2015/11/23/ijlct.ctv029