Skip to main content

Research Repository

Advanced Search

MRI tagging of colonic chyme mixing in healthy subjects: Inter‐observer variability and reliability of the measurement with time

Alshammari, Meshari T.; Alyami, Ali S.; Wilkinson-Smith, Victoria; Spiller, Robin C.; Gowland, Penny; Marciani, Luca; Moran, Gordon W.; Hoad, Caroline L.

Authors

Meshari T. Alshammari

Ali S. Alyami

Victoria Wilkinson-Smith

Profile Image

ROBIN SPILLER ROBIN.SPILLER@NOTTINGHAM.AC.UK
Professor of Gastroenterology

Profile Image

LUCA MARCIANI LUCA.MARCIANI@NOTTINGHAM.AC.UK
Professor of Gastrointestinal Imaging

GORDON MORAN GORDON.MORAN@NOTTINGHAM.AC.UK
Professor of Gastroenterology

CAROLINE HOAD CAROLINE.L.HOAD@NOTTINGHAM.AC.UK
Senior Research Fellow



Abstract

Background: Magnetic resonance imaging (MRI) tagging techniques have been applied to the GI tract to assess bowel contractions and content mixing. We aimed to evaluate the dependence of a tagging measurement (for assessing chyme mixing) on inter-observer variability in both the ascending colon (AC) and descending colon (DC) and to investigate the temporal variation and hence reliability of the colonic tagging technique by acquiring multiple measurements over time on healthy participants. Methods: Two independent datasets of healthy adults were used for the retrospective inter-observer variability (Study 1: 13 datasets and Study 2: 31 datasets), and ten participants were scanned for the prospective temporal variation study following a 1 L mannitol oral preparation. All colonic tagging data were acquired on 3 T MRI scanners. The mean and the standard deviation (SD) maps were generated pixel-by-pixel using custom-written software in MATLAB. The colonic regions of interest were defined using MIPAV software. Bland–Altman plots and scatter plots were used for the inter-observer variability. The mean and SD of all repeated measures for each subject were calculated along with a one-way ANOVA to test for variations with time. Results: Scatter plots and Bland–Altman plots showed a large range of data with low variation and small limits of agreements (<5% CoV). The intraclass correlation coefficient of inter-rater reliability was excellent and 0.97 or above for the AC and DC measurements for both datasets. The temporal variation study shows that there was no significant difference found between the multiple measures with time (p = 0.53, one-way repeated measures ANOVA test). Conclusions: MRI tagging technique can provide an assessment of colonic chyme mixing. The inter-observer study data showed high inter-rater agreement. The temporal variation study showed some individual variations with time suggesting multiple measurements may be needed to increase accuracy.

Citation

Alshammari, M. T., Alyami, A. S., Wilkinson-Smith, V., Spiller, R. C., Gowland, P., Marciani, L., …Hoad, C. L. (2023). MRI tagging of colonic chyme mixing in healthy subjects: Inter‐observer variability and reliability of the measurement with time. Neurogastroenterology and Motility, 35(8), Article e14610. https://doi.org/10.1111/nmo.14610

Journal Article Type Article
Acceptance Date Apr 27, 2023
Online Publication Date May 9, 2023
Publication Date 2023-08
Deposit Date May 18, 2023
Publicly Available Date May 10, 2024
Journal Neurogastroenterology & Motility
Print ISSN 1350-1925
Electronic ISSN 1365-2982
Publisher Wiley
Peer Reviewed Peer Reviewed
Volume 35
Issue 8
Article Number e14610
DOI https://doi.org/10.1111/nmo.14610
Keywords magnetic resonance imaging, colonic tagging, IBD, bowel motility, colonic chyme
Public URL https://nottingham-repository.worktribe.com/output/20566983
Publisher URL https://onlinelibrary.wiley.com/doi/10.1111/nmo.14610